Signal NVR2716 Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 51
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
- 15 -
3
Scan
PTZ also can work on the preset scan line repeatedly.
1Scan setup
Setting steps:
Step1: In Picture 2.5.5.0, click Setup button enter Picture 2.5.5.4
Step2: Click Scan buttonthe input proper value in the scan value blank;
Step3:Click Start button, enter Picture2.5.5.0,here you can set the following items:
Zoom,Focus,Aperture,Direction and so on. Click Setup button to go back Picture 2.5.5.4
Step4: Click End button to complete setup.Click the right button of the mouse to exit.
Pic 2.5.5.4 Scan Setup
2Scan Calls
In Picture2.5.5.0, click Page Switch button, then enter PTZ control menu as shown in Picture
2.5.5.2. Please input the number of scan in the value blank , then click Scan buttonPTZ begins to work
on the scan line . Click Stop button to stop.
4
Boundary Scan
In a horizontal lineset up a linecall scanPZT repeat operation according to the route
1Boundary Scan setup
Set a period of horizontal curve for PTZ search path,the steps are as follows:
Step1In Picture 2.5.5.0, click Direction button to turn the PTZ to preset direction, then click
Setup button enter Picture 2.5.5.5, select the left boundary, return to Picture 2.5.5.0;
Step2 Please click direction arrows to adjust PTZ direction, click Setup button enter
Picture2.5.5.5, then select the right boundary ,return to Picture2.5.5.0;
Step3: Complete setup, that is the position of left and right boundary
Note:when the left and right scan in one horizontal,the PTZ will cycle rotate from left scan along the
Scan value blank
Scan Button
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 50 51